Transmural fiber rotation alters the orientation of interstitial and transmembrane potentials in the depth of the tissue during bipolar epicardial stimulation without changing the total polarized volume.
Answers are grounded in this paper and cite their sources.
Rotated fibers reorient potentials in myocardial depth without changing polarized volume; leaves open translation to human epicardial stimulation.
A bidomain model of cardiac tissue was used to examine the effect of transmural fiber rotation during bipolar stimulation in three-dimensional (3-D) myocardium. A 3-D tissue block with unequal anisotropy and two types of fiber rotation (none and moderate) was stimulated along and across fibers via bipolar electrodes on the epicardial surface, and the resulting steady-state interstitial (phi e) and transmembrane (Vm) potentials were computed. Results demonstrate that the presence of rotated fibers does not change the amount of tissue polarized by the point surface stimuli, but does cause changes in the orientation of phi e and Vm in the depth of the tissue, away from the epicardium. Further analysis revealed a relationship between the Laplacian of phi e, regions of virtual electrodes, and fiber orientation that was dependent upon adequacy of spatial sampling and the interstitial anisotropy. These findings help to understand the role of fiber architecture during extracellular stimulation of cardiac muscle.
No takes yet. Share an insight, caveat, or question.
Muzikant et al. (1998) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: