Specific radioimmunoassays, sensitive to plasma levels of less than 1% of normal, were developed for protein C and Factor X. In 31 normal subjects, mean plasma antigen levels were as follows: protein C, 3.23 +/- 0.79 microgram/mL (2 SD); Factor X, 7.74 +/- 1.81 microgram/mL. In patient son chronic warfarin therapy, protein C and factor X were depressed equivalently: protein C, 42% +/- 20% (of a pooled plasma reference); Factor X, 44% +/- 24%. Protein C antigen fell much more rapidly than Factor X antigen when warfarin therapy was begun, creating an initial period of potential hypercoagulability. In patients with severe liver disease, mean protein C antigen (25% +/- 17%) was lower than Factor X antigen (51% +/- 29%). Protein C antigen levels did not appear to be a sensitive indicator of compensated intravascular coagulation or systemic fibrinolysis induced by infusion of streptokinase. Clinical implications of these findings are discussed.