A modified Bentall procedure using prosthetic replacement can be successfully performed for the rare condition of isolated ascending aortic prosthetic graft endocarditis.
Answers are grounded in this paper and cite their sources.
Raises suspicion for culture-negative prosthetic endocarditis; leaves open optimal diagnostic strategies in similar patients.
We report a case of a 40 years old male who was presented to the hospital with fever and fatigue that has persisted more than 2 weeks. Physical examination revealed a high fever and laboratory findings revealed an elevated CRP. Blood cultures tested negative. Patient had a mechanical aortic valve replacement surgery 22 years ago and supracoronary ascending aortic replacement surgery 9 years ago. He also had a history of permanent pacemaker implantation due to atrioventricular block after the second surgery. He applied to our clinic and had continued medical treatment for one more week. Transesophageal echocardiography and fludeoxyglucose F18 PET/CT revealed a vegetation on the proximal part of ascending aortic prosthetic graft and moderate gradient on aortic prosthetic vale. He was diagnosed with endocarditis of ascending aortic prosthetic graft and moderate aortic stenosis. A patient was referred for surgery at our clinic. We perform a modified Bentall procedure with 23mm mechanical aortic valve and 28 mm Dacron graft with removal of all the prosthetic material from foregoing surgeries because of immediate neighborhood except the pacemaker wire and battery (Pic. 1). Postoperative period was uneventful and he was discharged on postoperative 7 th day. Postoperative transthoracic echocardiography revealed normal findings of aortic valve and prosthetic aortic graft. Isolated AAPG endocarditis is a rare case and homograft may be an option especially in young patients like ours. However it was found convenient to use prosthetic replacement Pic. 1 Picture of infected ascending aorta prosthetic graft after removal. References 1. Ramos A, García-Montero C, Moreno A, et al. Endocarditis in patients with ascending aortic prosthetic graft: a case series from a national multicentre registry. Eur J Cardiothorac Surg 2016;50(6):1149–1157 10.1093/ejcts/ezw190 PubMed 2. Carrasco F, Anguita M. MartÃn Ruiz, Juan Carlos Castillo, Mà 3 nica Delgado, Dolores Mesa, Elias Romo, Manuel Pan, Jose SuÃꁅrez de Lezo, Clinical features and changes in epidemiology of infective endocarditis on pacemaker devices over a 27-year period (1987–2013), EP Europace, Volume 18, Issue 6, June 2016, Pages 836–841, https://doi.org/10.1093/europace/euv377 3. Hagl C, Galla JD, Lansman SL, et al. Replacing the ascending aorta and aortic valve for acute prosthetic valve endocarditis: is using prosthetic material contraindicated? Ann Thorac Surg 2002;74(5):S1781–S1785, discussion S1792–S1799 10.1016/s0003-4975(02)04142-5 PubMed 4. Lengyel M. The impact of transesophageal echocardiography on the management of prosthetic valve endocarditis: experience of 31 cases and review of the literature. J Heart Valve Dis 1997;6(2):204–211 PubMed Publication History Article published online: 10 June 2022 © 2022. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/) Thieme Medical Publishers, Inc. 333 Seventh Avenue, 18th Floor, New York, NY 10001, USA
No takes yet. Share an insight, caveat, or question.
Koyuncu et al. (2022) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: