Electromagnetic field localization in a subwavelength metallic slit by a thermo-elastic optical indicator microscope (TEOIM) was investigated. As an indicator for the TEOIM system a slide glass with sizes of 20× 20×0.5~(mm) was used, on the surface of which an Al film of $20~nm$ thickness was vaporized using the vacuum evaporation technique, with various slit width (10-50~μ m). Strongly localized electromagnetic field has been exited in the slits by $50~ GHz$ generator and was visualized by a TEOIM. The waveguide properties of the system were characterized by COMSOL Multiphysics^ additionally. The simulation results are in good agreement with the visualization data set.
No takes yet. Share an insight, caveat, or question.
Sh.Kh. Arakelyan (2017) studied this question.