The performance of the half-bridge (HB) zero-current-switched (ZCS) quasi-resonant converter (QRC) and zero-voltage-switched (ZVS) multiresonant converter (MRC) is compared with respect to their efficiency, input voltage range, semiconductor stresses, power density, and reliability. The efficiency of the HB ZVS-MRC at a given nominal input is shown to be highly dependent on the range of the input voltage, and it suffers when the converter has to be designed to cover a wide range. However, this is not the case for the HB ZCS-QRC. Experimental versions of the HB ZCS-QRC and HB ZVS-MRC were designed for the input voltage range from 150 to 350 V and a maximum output power of 100 W, under the same constraints, to facilitate their comparison.>
No takes yet. Share an insight, caveat, or question.
Jovanovic et al. (1990) studied this question.