Answers are grounded in this paper and cite their sources.
PURPOSE: To describe a new pathophysiological mechanism for endotension. CASE REPORTS: Four patients developed aneurysm sac expansion after repair of abdominal aortic aneurysms, one with a conventional polytetrafluoroethylene (PTFE) graft and the others with a variety of commercially made endografts (2 PTFE, 1 Dacron). Pressures within the sacs were nonpulsatile and approximately half the systemic blood pressure. Attenuation on computed tomography (CT) was significantly less in the sac than in the graft in 3 of the patients. A clear, highly viscous fluid was aspirated from all 4 sacs, supporting the diagnosis of aneurysm sac hygroma. Prominent local hyperfibrinolysis in the sac was combined with signs of local coagulation activation. CONCLUSIONS: A new mechanism for continued sac expansion based on aneurysm sac hygroma is proposed. Measurement of attenuation may be of diagnostic value. It is further proposed that local hyperfibrinolysis/coagulation may promote rebleeding, liquefaction, and continued expansion analogous to the chronic subdural hematoma.
No takes yet. Share an insight, caveat, or question.
Risberg et al. (2001) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: