Answers are grounded in this paper and cite their sources.
The study deals with the manufacture and testing of an arc-shaped and a rectangular fly-eye mirror used in an extreme ultraviolet lithography system. Both mirrors have a complex reflective surface consisting of many mirror elements. The function of the mirrors is that an arc field can be illuminated uniformly by the integration of rays from the mirror elements. In this study, a fabrication method for the mirrors, in which ultraprecision 5-axis control milling was adopted, was discussed. By using this method, the mirrors with sixteen mirror elements ware fabricated. Furthermore, the mirrors were tested by measuring rays reflected from them. As a result, the rays were successfully integrated on the arc field, demonstrating that the mirrors were acurately fabricated. However, the surfaces of the mirror elements had waviness with a height of ten nenometers order, causing uneven illumination on the arc field. This finding indicates that the waviness on the surfaces must be removed to achieve high uniformity of the illumination.
No takes yet. Share an insight, caveat, or question.
Sumita et al. (2004) studied this question.