Why the study?
Paravalvular leak severity, size, shape, and morphology affect clinical presentation and heart failure severity, and real-time 3D TEE provides additional information over 2D TEE regarding complex 3D anatomy. This study examined the relationship between echocardiographic findings and the development of hemolysis.
Do echocardiographic findings from 2D and RT-3D TEE correlate with the development of hemolysis in patients with severe mitral paravalvular leaks?
Observational (n=108)
Do echocardiographic findings from 2D and RT-3D TEE correlate with the development of hemolysis in patients with severe mitral paravalvular leaks?
Answers are grounded in this paper and cite their sources.
Unestablished link between TEE parameters and hemolysis in mitral PVL; leaves open whether imaging refines risk stratification.
Purpose: Paravalvular leak (PVL) is not an uncommon complication of valve surgery.PVL severity, size, shape and morphology are important factors in determining subsequent clinical presentation and the severity of heart failure.Symptoms may be due to hemolytic anemia as a result of hemolysis.RT-3D TEE is superior over 2D TEE as it provides additional information about the complex 3D anatomy.Methods: The study was comprised of 108 patients with severe mitral PVLs.The PVLs were visualized using two dimensional transesophageal echocardiography (2D TEE) and subsequent real time three dimensional transesophageal echocardiography (RT-3D TEE).The relationship between echocardiographic findings and development of hemolysis were studied.The presence and severity of hemolysis was assessed on the basis of serum lactic dehydrogenase, blood hemoglobin, bilirubin and reticulocyte levels.Results: The study group included mechanical (n= 98) and bioprosthetic valves (n= 10).The most common PVL localizations were anterolateral commisure, posteromedial commissures and posterolateral region.The mean PVL width measured by 2D TEE was 3.2 + 1.5 (range; 2-7) mm and the mean width of defect measured by 3D TEE was 3.1 + 1.7 (range; 2-7) mm (p= 0.6).The mean length of defect measured by 3D TEE was 12.5 + 7 (range; 4-22) mm.The mean area of severe PVLs was 35 + 25 mm2 (range; 8-100).Fifty-six patients (52 %) PVLs were oval/round shaped whereas 34 (31 %) were cresentric, 11 (10 %) were slit-like and 5 (5 %) were slope-tunnel shaped.Two posteriorly-localized defects (2 %) were not clearly visualized by RT-3D TEE.Nine cresentic-shaped (8%) and 4 slit-like shaped (% 4) PVLs were 'multi-fenestrated'.Besides, 74 % of the cresentic shaped leaks had irregular borders (n=25).The oval / round, tunnel-like and slit-like defects had regular borders.The patients were followed-up for 4 + 0.8 years.Hemolysis was observed in 65 (60 %) patients.The patients with cresentic and irregular defects had significantly higher severity of hemolysis compared to the others (p=0.02).The size of the defect did not correlate with severity of hemolysis.Conclusions: RT-3D TEE permits detailed structural evaluation of paravalvular leak shape which may contribute to the severity of hemolysis.
No takes yet. Share an insight, caveat, or question.
Kalçık et al. (2013) conducted an observational in Severe mitral paravalvular leak (PVL) (n=108). Real time three dimensional transesophageal echocardiography (RT-3D TEE) evaluation of crescentic and irregular PVL defects vs. Two dimensional transesophageal echocardiography (2D TEE) / other PVL defect shapes was evaluated on Presence and severity of hemolysis (p=0.02).