This paper introduces the MAGnetometer-Inertial sensors Calibration and ALignment (MAG.I.C.AL.) methodology for unified calibration and joint axes alignment of three-axis magnetometer, three-axis accelerometer, and three-axis gyroscope. MAG.I.C.AL. compensates for all linear time-invariant distortions such as scale-factor, cross-coupling, and offset, including the soft-iron and hard-iron distortions of the magnetometer. It introduces a new, computationally efficient, least-squares-based iterative algorithm for the calibration of the magnetometer and the accelerometer. It aligns their axes and introduces a new way to calibrate the gyroscope based on their joint data. MAG.I.C.AL. is implemented in a 15-step sequence achieving fast convergence and high accuracy without using any external piece of equipment and without requiring external attitude references. Simulation and experimental results using low-cost sensors are presented to support the accuracy, efficiency, and the applications of the algorithm.
No takes yet. Share an insight, caveat, or question.
Papafotis et al. (2019) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: