Removing solvents from nanoparticle solid suspensions requires the same diligence as drying pharmaceutical ingredients. nanoparticles suspension in water oxidize, sinter, and segregates on the surface when they dry in a furnace. Spray drying preserves the material properties because contact times are on the orders of seconds; furthermore, the atomized droplets ensure particles are small (5 m to 20 m) and dispersed. A Yamato GA‐32 (120 mm inner diameter) spray dried in co‐current flow a nanoparticle suspension of in water, with a solid content up to 60 %. Atomization gas velocities of 140 m s to 350 m s agglomerated the nanomaterial into spherical particles that ranged from 3 m to 10 m. The particle diameters ranged from 10 m to 20 m at atomization velocities of 50 m s to 140 m s . At this condition, yield was lower because the semi‐dried particles adhere on the wall. At 150 C to 200 C the surface area reached 26 m g while from 50 C to 100 C it varied from 14 m g to 20 m g . The trend for mesoporosity versus spray drying temperature is the same as for surface area: pore volumes are higher (0.18 cm g ) above 200 C and 20 % lower below 200 C. Drying temperature modifies drying speed; low temperatures compact the powders more than high temperature which results in lower surface area and porosity.
No takes yet. Share an insight, caveat, or question.
Rigamonti et al. (2017) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: