Answers are grounded in this paper and cite their sources.
Layer uniformity was improved by using a wire mask in the fabrication of a coarse wavelength division multiplexer (CWDM) filter. Theoretical simulations determined the optimal diameter of the wire to be placed just below the substrate, which was rotated at 800 rpm during E-beam evaporation. This simulation also demonstrated the correction of the thickness distribution by the etching effect of ion-assisted deposition. In the corresponding experiment, a distribution uniformity of 0.083% in the radial range from 35 to 65 mm was achieved by the coating of the CWDM filter.
No takes yet. Share an insight, caveat, or question.
Jin–Cherng Hsu (2014) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: