Theoretical techniques which were developed for the study of errors and error compensation in the turning value monitoring of thin-film narrow-band filters are applied to the monitoring of broad-band components, especially anti-reflection coatings and edge filters. The technique of pre-coating the test plate in semi-direct monitoring is examined. It is shown that in the turning value monitoring of broad-band components the most important factor is the small consistent overshoot made by experienced plant operators and that, to be effective, a pre-coating must minimize the interactions between errors caused by the successive overshoots. Techniques for predicting the magnitudes of such interactions are given. The stability of an alternative technique for edge filters, that of semi-direct level monitoring, is considered and the way in which pre-coatings can improve the accuracy of edge position demonstrated.