In this paper, we present four design methods to overcome (100) silicon crystalline anisotropy and achieve mode-matching in wineglass-mode disk resonator gyroscope (DRG). These methods were validated through experimental characterization of more than 145 different devices that arose from simulations. With the proposed methods, the frequency split of the 250-kHz DRG wineglass modes in (100) silicon was reduced from >10 kHz to as low as 96 Hz (<;0.04% of 250-kHz resonant frequency) without any electrostatic tuning. Perfect mode-matching is then achieved using electrostatic tuning. Mode-matching was maintained within ±10 Hz over a temperature range from -20 °C to 80 °C. The temperature dependence of quality factor is also discussed in this paper. These results allow for the development of high-performance miniature DRGs tuned for degenerate wineglass mode operation from high-quality crystalline silicon material.
No takes yet. Share an insight, caveat, or question.
Ahn et al. (2014) studied this question.
Synapse has enriched 3 closely related papers on similar clinical questions. Consider them for comparative context: