Key result
Automated planar patch-clamp systems record 384 cells in parallel, yielding ~30,000 daily data points.
Automated patch clamp and multi-electrode array technologies provide advanced, higher-throughput methods for screening ion channel-targeting drugs and assessing cardiac safety.
Answers are grounded in this paper and cite their sources.
Automated patch-clamp systems may accelerate ion channel drug screening and cardiac safety assays; leaves open routine integration into clinical research workflows.
Ion channels are integral membrane proteins that regulate the flux of ions across the cell membrane. They are involved in nearly all physiological processes, and malfunction of ion channels has been linked to many diseases. Until recently, high-throughput screening of ion channels was limited to indirect, e.g. fluorescence-based, readout technologies. In the past years, direct label-free biophysical readout technologies by means of electrophysiology have been developed. Planar patch-clamp electrophysiology provides a direct functional label-free readout of ion channel function in medium to high throughput. Further electrophysiology features, including temperature control and higher-throughput instruments, are continually being developed. Electrophysiological screening in a 384-well format has recently become possible. Advances in chip and microfluidic design, as well as in cell preparation and handling, have allowed challenging cell types to be studied by automated patch clamp. Assays measuring action potentials in stem cell-derived cardiomyocytes, relevant for cardiac safety screening, and neuronal cells, as well as a large number of different ion channels, including fast ligand-gated ion channels, have successfully been established by automated patch clamp. Impedance and multi-electrode array measurements are particularly suitable for studying cardiomyocytes and neuronal cells within their physiological network, and to address more complex physiological questions. This article discusses recent advances in electrophysiological technologies available for screening ion channel function and regulation.
No takes yet. Share an insight, caveat, or question.
Obergrussberger et al. (2015) conducted a review in Ion channel malfunction and drug-induced cardiac arrhythmia. Automated planar patch-clamp electrophysiology, impedance, and multi-electrode array systems vs. Conventional patch clamp and indirect fluorescence-based readout technologies was evaluated. Automated planar patch-clamp systems like the SyncroPatch 384PE record from 384 cells in parallel, achieving a throughput of 20,000-38,000 data points per day for ion channel screening.
Synapse has enriched 10 related papers. Consider them for comparative context: