Key result
Persistent or new Cornell product ECG LVH at 3 years was associated with higher odds of abnormal half filling time (OR 1.63; 95% CI 1.04-2.55; p=0.034) in hypertensive patients.
Why the study?
Is persistent or new Cornell product ECG left ventricular hypertrophy associated with worse left ventricular diastolic function in hypertensive patients with preserved LVEF?
Cohort (n=377)
Is persistent or new Cornell product ECG left ventricular hypertrophy associated with worse left ventricular diastolic function in hypertensive patients with preserved LVEF?
In hypertensive patients, persistent or new ECG left ventricular hypertrophy is modestly associated with left ventricular diastolic dysfunction, suggesting a potential mechanism for increased heart failure risk.
May link persistent ECG LVH to diastolic issues; hypothesis-generating and should not change practice.
BACKGROUND: Persistence or development of Cornell product left ventricular hypertrophy (LVH) is associated with increased heart failure (HF) risk that is partly explained by greater LV systolic dysfunction. However, whether new or persistent Cornell product LVH during antihypertensive treatment is associated with worse LV diastolic function is unclear. METHODS: Left ventricular diastolic function was examined in relation to year-3 ECG LVH in 377 hypertensive patients with a preserved LV ejection fraction (>45%) at year-3. Cornell product >2440 mm·ms defined ECG LVH. RESULTS: In multivariate models adjusting for age, sex, change from baseline to year-3 systolic blood pressure, and baseline and change from baseline to year-3 Sokolow-Lyon voltage, persistent or new Cornell product LVH at year-3 remained associated with year-3 abnormal half filling time (OR 1.63, 95% CI 1.04-2.55 p = 0.034), with a trend toward higher odds of abnormal third filling time (OR 1.51, 95% CI 0.087 p = 0.087) and total filling time (OR 1.79, CI 0.98-3.27 p = 0.059). CONCLUSION: In hypertensive patients undergoing antihypertensive therapy, persistence or development of Cornell product ECG LVH at year-3 follow-up is modestly associated with LV diastolic dysfunction. These findings suggest that diastolic dysfunction may be a mechanism via which changing ECG LVH influences HF risk.
No takes yet. Share an insight, caveat, or question.
Tanoue et al. (2016) conducted a cohort in Hypertension with preserved LV ejection fraction (n=377). Persistent or new Cornell product ECG LVH vs. Absence of persistent or new Cornell product ECG LVH was evaluated on Abnormal half filling time at year-3 (OR 1.63, 95% CI 1.04-2.55, p=0.034). Persistent or new Cornell product ECG LVH at 3 years was associated with higher odds of abnormal half filling time (OR 1.63; 95% CI 1.04-2.55; p=0.034) in hypertensive patients.