January 1, 1996European Journal of Cardio-Thoracic SurgeryOpen Access

Pericardial valves in small aortic annuli: ten years' results

View Full Paper
Ask AI
Bookmark
Share

Why the study?

Does the 19 mm Carpentier-Edwards pericardial bioprosthesis provide reliable long-term clinical and structural outcomes in patients with small aortic annuli?

Population

90 patients who underwent an isolated aortic valve replacement with a 19 mm Carpentier-Edwards pericardial…

Design

Cohort

Follow-up

average 4.45 years

Authors

MAMichel AupartCardiac SurgeryISI SIMONNOTASA SirinelliCentre Hospitalier Universitaire de Tours

Discussion

Loading...

Member takes

Implication

Supports durability of 19 mm pericardial bioprostheses in small annuli; leaves open randomized comparisons.

Structured PICO

Does the 19 mm Carpentier-Edwards pericardial bioprosthesis provide reliable long-term clinical and structural outcomes in patients with small aortic annuli?

P
Population
90 patients who underwent an isolated aortic valve replacement with a 19 mm Carpentier-Edwards pericardial bioprosthesis, mean age 72.2 +/- 10.1 years, 50% in NYHA clinical status III or IV.
I
Intervention
19 mm Carpentier-Edwards pericardial bioprosthesis for isolated aortic valve replacement
O
Outcome
Actuarial survival rate and freedom from valve-related death at 10 yearshard clinical

The 19 mm Carpentier-Edwards pericardial bioprosthesis demonstrates low rates of structural deterioration and valve-related events at 10 years, making it a reliable option for patients with small aortic annuli.

Cite This Study

Aupart et al. (1996) studied this question.

synapsesocial.com/papers/6a75bae61eaff9cba916155ahttps://doi.org/10.1016/s1010-7940(96)80315-0
View Full Paper
Ask AI
Bookmark
Share

Also Consider

Synapse has enriched 4 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1The Carpentier-Edwards pericardial aortic valve: intermediate results in 420 patients1994 · 17 citations
  2. 2Long-Term Evaluation of the Carpentier-Edwards Pericardial Valve in the Aortic Position1991 · 36 citations
  3. 3Long-term follow-up of patients with the antibiotic-sterilized aortic homograft valve inserted freehand in the aortic position.1987 · 202 citations
  4. 4Doppler echocardiographic assessment of the St. Jude Medical prosthetic valve in the aortic position using the continuity equation.1991 · 173 citations