Key result
Following CABG, mean peak hs-cTnI reached 126× URL and hs-cTnT reached 45× URL at 6-8 hours, surpassing most current diagnostic cutoff values.
Why the study?
Current type 5 myocardial infarction definitions arbitrarily use troponin cutoffs based on conventional assays and do not differentiate between troponin I and T.
Do the kinetics of high-sensitivity cardiac troponin I and T differ following coronary artery bypass grafting?
Meta-Analysis (n=4,307)
Do the kinetics of high-sensitivity cardiac troponin I and T differ following coronary artery bypass grafting?
Postoperative hs-cTnI and hs-cTnT following CABG surpass most current diagnostic cutoff values for type 5 MI, with hs-cTnI peaking almost 3-fold higher than hs-cTnT, highlighting the need for assay-specific cutoffs.
Answers are grounded in this paper and cite their sources.
Current hs-cTn cutoffs may misclassify post-CABG injury; challenges perioperative MI diagnostics and supports surgery-specific thresholds.
BACKGROUND: Cardiac troponin I and T are both used for diagnosing myocardial infarction (MI) after coronary artery bypass grafting (CABG), also known as type 5 MI (MI-5). Different MI-5 definitions have been formulated, using multiples of the 99th percentile upper reference limit (10×, 35×, or 70× URL), with or without supporting evidence. These definitions are arbitrarily chosen based on conventional assays and do not differentiate between troponin I and T. We therefore investigated the kinetics of high-sensitivity cardiac troponin I (hs-cTnI) and T (hs-cTnT) following CABG. METHODS: A systematic search was applied to MEDLINE and EMBASE databases including the search terms "coronary artery bypass grafting" AND "high-sensitivity cardiac troponin." Studies reporting hs-cTnI or hs-cTnT on at least 2 different time points were included. Troponin concentrations were extracted and normalized to the assay-specific URL. RESULTS: For hs-cTnI and hs-cTnT, 17 (n = 1661 patients) and 15 studies (n = 2646 patients) were included, respectively. Preoperative hs-cTnI was 6.1× URL (95% confidence intervals: 4.9-7.2) and hs-cTnT 1.2× URL (0.9-1.4). Mean peak was reached 6-8 h postoperatively (126× URL, 99-153 and 45× URL, 29-61, respectively). Subanalysis of hs-cTnI illustrated assay-specific peak heights and kinetics, while subanalysis of surgical strategies revealed 3-fold higher hs-cTnI than hs-cTnT for on-pump CABG and 5-fold for off-pump CABG. CONCLUSION: Postoperative hs-cTnI and hs-cTnT following CABG surpass most current diagnostic cutoff values. hs-cTnI was almost 3-fold higher than hs-cTnT, and appeared to be highly dependent on the assay used and surgical strategy. There is a need for assay-specific hs-cTnI and hs-cTnT cutoff values for accurate, timely identification of MI-5.
No takes yet. Share an insight, caveat, or question.
Denessen et al. (2022) conducted a meta-analysis in Coronary artery bypass grafting (CABG) (n=4,307). High-sensitivity cardiac troponin I (hs-cTnI) vs. High-sensitivity cardiac troponin T (hs-cTnT) was evaluated on Mean peak concentration postoperatively (multiples of URL). Following CABG, mean peak hs-cTnI reached 126× URL and hs-cTnT reached 45× URL at 6-8 hours, surpassing most current diagnostic cutoff values.
Synapse has enriched 10 related papers. Consider them for comparative context: