Key result
Full-root aortic valve replacement with stentless xenografts resulted in significantly lower mean transvalvular gradients at one year compared to stented valves (5.8 vs 13.9 mmHg, p<0.0001) and better regression of left ventricular mass index.
Why the study?
Does full-root aortic valve replacement with stentless xenografts improve hemodynamic outcomes and left ventricular mass index regression compared to stented valves in patients undergoing aortic valve replacement?
Cohort (n=260)
No
Does full-root aortic valve replacement with stentless xenografts improve hemodynamic outcomes and left ventricular mass index regression compared to stented valves in patients undergoing aortic valve replacement?
Full-root stentless aortic valve replacement provides superior mid-term hemodynamic performance and left ventricular mass index regression compared to stented valves in patients with aortic stenosis, without increasing early morbidity or mortality despite longer operative times.
Stentless full-root AVR may offer hemodynamic benefits in aortic stenosis; leaves open need for RCTs to confirm durability before practice change.
BACKGROUND: Full-root aortic valve replacement with stentless xenografts has potentially superior hemodynamic performance compared to stented valves. However, a number of cardiac surgeons are reluctant to transform a classical stented aortic valve replacement into a technically more demanding full-root stentless aortic valve replacement. Here we describe our technique of full-root stentless aortic xenograft implantation and compare the early clinical and midterm hemodynamic outcomes to those after aortic valve replacement with stented valves. METHODS: We retrospectively compared the pre-operative characteristics of 180 consecutive patients who underwent full-root replacement with stentless aortic xenografts with those of 80 patients undergoing aortic valve replacement with stented valves. In subgroups presenting with aortic stenosis, we further analyzed the intra-operative data, early postoperative outcomes and mid-term regression of left ventricular mass index. RESULTS: Patients in the stentless group were younger (62.6 ± 13 vs. 70.3 ± 11.8 years, p < 0.0001) but had a higher Euroscore (9.14 ± 3.39 vs.6.83 ± 2.54, p < 0.0001) than those in the stented group. In the subgroups operated for aortic stenosis, the ischemic (84.3 ± 9.8 vs. 62.3 ± 9.4 min, p < 0.0001) and operative times (246.3 ± 53.6 vs. 191.7 ± 53.2 min, p < 0.0001) were longer for stentless versus stented valve implantation. Nevertheless, early mortality (0% vs. 3%, p < 0.25), re-exploration for bleeding (0% vs. 3%, p < 0.25) and stroke (1.8% vs. 3%, p < 0.77) did not differ between stentless and stented groups. One year after the operation, the mean transvalvular gradient was lower in the stentless versus stented group (5.8 ± 2.9 vs. 13.9 ± 5.3 mmHg, p < 0.0001), associated with a significant regression of the left ventricular mass index in the stentless (p < 0.0001) but not in the stented group (p = 0.2). CONCLUSION: Our data support that full-root stentless aortic valve replacement can be performed without adversely affecting the early morbidity or mortality in patients operated on for aortic valve stenosis provided that the coronary ostia are not heavily calcified. The additional time necessary for the full-root stentless compared to the classical stented aortic valve replacement is therefore not detrimental to the early clinical outcomes and is largely rewarded in patients with aortic stenosis by lower transvalvular gradients at mid-term and a better regression of their left ventricular mass index.
No takes yet. Share an insight, caveat, or question.
Tavakoli et al. (2015) conducted a cohort in Aortic valve disease (aortic stenosis and regurgitation) (n=260). Full-root aortic valve replacement with stentless xenograft vs. Aortic valve replacement with stented pericardial valves was evaluated on Mean transvalvular gradient at 1 year (mmHg) (p=<0.0001). Full-root aortic valve replacement with stentless xenografts resulted in significantly lower mean transvalvular gradients at one year compared to stented valves (5.8 vs 13.9 mmHg, p<0.0001) and better regression of left ventricular mass index.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: