Key result
An error compensation method improved the accuracy of heart rate variability analysis in time domain, frequency domain, and non-linear analysis for both PPG and ECG.
Why the study?
Heart rate variability indices are affected by heartbeat interval mismatches from measurement hardware sampling errors and inherent physiological differences between PPG and ECG in wearable devices.
Does an error compensation method improve the accuracy of HRV analysis using ECG and PPG in human subjects?
Does an error compensation method improve the accuracy of HRV analysis using ECG and PPG in human subjects?
An error compensation algorithm improves the accuracy of heart rate variability analysis derived from both ECG and PPG wearable sensors.
Error compensation may enhance wearable HRV reliability; leaves open clinical adoption pending validation.
The purpose of this study is to evaluate the effectiveness of heartbeat error and compensation methods on heart rate variability (HRV) with mobile and wearable sensor devices. The HRV analysis extracts multiple indices related to the heart and autonomic nervous system from beat-to-beat intervals. These HRV analysis indices are affected by the heartbeat interval mismatch, which is caused by sampling error from measurement hardware and inherent errors from the state of human body. Although the sampling rate reduction is a common method to reduce power consumption on wearable devices, it degrades the accuracy of the heartbeat interval. Furthermore, wearable devices often use photoplethysmography (PPG) instead of electrocardiogram (ECG) to measure heart rate. However, there are inherent errors between PPG and ECG, because the PPG is affected by blood pressure fluctuations, vascular stiffness, and body movements. This paper evaluates the impact of these errors on HRV analysis using dataset including both ECG and PPG from 28 subjects. The evaluation results showed that the error compensation method improved the accuracy of HRV analysis in time domain, frequency domain and non-linear analysis. Furthermore, the error compensation by the algorithm was found to be effective for both PPG and ECG.
No takes yet. Share an insight, caveat, or question.
Shintomi et al. (2022) studied this question. Error compensation method was evaluated on Accuracy of HRV analysis in time domain, frequency domain and non-linear analysis. An error compensation method improved the accuracy of heart rate variability analysis in time domain, frequency domain, and non-linear analysis for both PPG and ECG.