Key result
High-resolution body surface potential mapping demonstrated higher sensitivity but lower specificity than standard 12-lead ECG for detecting myocardial ischemia during exercise stress testing.
Why the study?
Does high-resolution body surface potential mapping (HR-BSPM) improve the detection of myocardial ischemia during exercise stress testing compared to standard 12-lead ECG in patients with stable coronary artery disease?
Cross-Sectional (n=43)
No
Does high-resolution body surface potential mapping (HR-BSPM) improve the detection of myocardial ischemia during exercise stress testing compared to standard 12-lead ECG in patients with stable coronary artery disease?
High-resolution body surface potential mapping during exercise stress testing improves the sensitivity of detecting myocardial ischemia compared to standard 12-lead ECG, though with a slight reduction in specificity.
Answers are grounded in this paper and cite their sources.
May increase ischemia detection sensitivity during stress testing; hypothesis-generating and should not yet change practice.
INTRODUCTION: The aim of the study was to assess myocardial ischemia by analysis of ST-segment changes in high-resolution body surface potential maps (HR-BSPM) measured at rest and during an exercise stress test. MATERIAL AND METHODS: The study was carried out on a group of 28 patients with stable coronary artery disease and 15 healthy volunteers. The HR-BSPM were measured at rest and during the exercise stress test on a supine ergometer. The workload was increased in stages by 25 W every 2 min, beginning at 50 W. The maps of ST-segment depression (ST60) were calculated from time averaged recordings at rest and at maximal workload. RESULTS: The efficiency in detection of myocardial ischemia was higher for HR-BSPM than for standard 12-lead electrocardiography (ECG) when both methods were evaluated by outcomes of coronarography. The sensitivity of HR-BSPM was 82.4% while for the standard 12-lead ECG exercise stress test it was 58.8%. For some patients significant changes in the ST segment were observed at stress HR-BSPM but were not visible in standard 12-lead ECG recorded under the same conditions. CONCLUSIONS: Obtained high values of sensitivity and specificity in myocardial ischemia detection suggest that maps of ST60 calculated from HR-BSPM can improve detection of patients with ischemic heart disease in comparison to the standard electrocardiographic exercise stress test examinations.
No takes yet. Share an insight, caveat, or question.
Kania et al. (2014) conducted a cross-sectional in Stable coronary artery disease (n=43). High-resolution body surface potential mapping (HR-BSPM) vs. Standard 12-lead ECG was evaluated on Sensitivity for detection of myocardial ischemia. High-resolution body surface potential mapping demonstrated higher sensitivity but lower specificity than standard 12-lead ECG for detecting myocardial ischemia during exercise stress testing.
Synapse has enriched 10 related papers. Consider them for comparative context: