Key result
The LocaLisa system reduced total fluoroscopy time during radiofrequency ablation of atrial flutter compared with a conventional approach.
Why the study?
Does the LocaLisa system reduce fluoroscopy time and dosage compared to conventional fluoroscopy in patients undergoing ablation of atrial flutter?
RCT (n=50)
Does the LocaLisa system reduce fluoroscopy time and dosage compared to conventional fluoroscopy in patients undergoing ablation of atrial flutter?
The LocaLisa nonfluoroscopic navigation system significantly reduces fluoroscopy time and radiation dose during radiofrequency ablation of typical atrial flutter without compromising procedural success.
Answers are grounded in this paper and cite their sources.
Reduces radiation exposure risk in atrial flutter ablation; extends randomized evidence for nonfluoroscopic navigation in electrophysiology.
INTRODUCTION: Catheter ablation has become a well-established therapy for isthmus-dependent right atrial flutter (AFL). Recently, mapping and ablation of AFL have been performed using sophisticated three-dimensional mapping systems, such as electroanatomic and noncontact mapping systems. The LocaLisa system enables nonfluoroscopic navigation of intracardiac electrode catheters based on impedance changes related to catheter movements in transthoracic current fields. The aim of this randomized prospective study was to compare the efficacy of the LocaLisa system with the conventional mapping/ablation approach for radiofrequency ablation of AFL. METHODS AND RESULTS: Fifty consecutive patients with AFL (39 men and 11 women; age 65 +/- 10 years) were studied. The patients were randomly assigned to undergo radiofrequency ablation guided by a conventional fluoroscopy-based approach (24 patients) or by the LocaLisa system (26 patients). Ablation success rate and documentation of bidirectional isthmus block were 100% in both groups. Compared with fluoroscopy-guided approaches, LocaLisa-guided procedures demonstrated a reduction in total fluoroscopy time from 15.9 +/- 10.6 minutes to 7.5 +/- 6.5 minutes (P < 0.005). Total fluoroscopy dosage was reduced from 21.0 +/- 19.8 to 8.7 +/- 9.5 Gycm2 (P < 0.05). Fluoroscopy time required for ablation was significantly shortened in the LocaLisa group (2.6 +/- 2.6 min) compared with the conventional approach group (11 +/- 10 min, P < 0.0005). In 9 (35%) of 26 patients, the ablation could be performed with a fluoroscopy time < or = 1 minute. There were no significant differences with regard to the number of radiofrequency applications, fluoroscopy time needed for diagnostic reasons, total procedure time, or other ablation data. CONCLUSION: Compared with the conventional approach, the LocaLisa system significantly reduces the fluoroscopy times needed for ablation of typical AFL.
No takes yet. Share an insight, caveat, or question.
Schneider et al. (2003) conducted an RCT in Atrial flutter (n=50). LocaLisa system vs. Conventional fluoroscopy-based approach was evaluated on Total fluoroscopy time (minutes) (p=< 0.005). The LocaLisa system reduced total fluoroscopy time during radiofrequency ablation of atrial flutter compared with a conventional approach.
Synapse has enriched 10 related papers. Consider them for comparative context: