Key result
Anesthesia induction in infants 0-10 weeks of age resulted in a mean arterial blood pressure decrease of 28.6%, whereas heart rates remained similar before and after induction.
Why the study?
What are the expected blood pressure and heart rate changes in children 0-5 years during anesthesia?
Observational (n=54,896)
What are the expected blood pressure and heart rate changes in children 0-5 years during anesthesia?
Anesthesia induction in infants 0-10 weeks old causes a significant decrease in mean arterial and systolic blood pressure, while heart rate remains a poor indicator of these changes.
Answers are grounded in this paper and cite their sources.
Marked blood pressure reduction during induction in young infants warrants close monitoring; leaves open optimal agent selection and mitigation strategies.
BACKGROUND: An acceptable systolic or mean arterial blood pressure for children 0-6 years during anesthesia is unknown. Accepted blood pressures reported in standard charts for healthy awake children may not apply to those undergoing anesthesia. AIM: Our goal was to define observed blood pressures (BP) and heart rate (HR) in children 0-5 years during anesthesia. METHODS: Data from the electronic health record database were available for a 10-year period from June 29, 2005 to July 22, 2015. A simple band-pass filter was applied to remove artifact in the physiologic time-series data for heart rate and blood pressure, with heart rate values 40 or above 250, mean or diastolic blood pressures below 20 or above 200, and systolic blood pressures below 30 or above 200 all excluded. For each anesthetic, the centiles of physiological variables (BP, HR) were calculated. RESULTS: Data were available for 54 896 anesthetics in children 6 years and younger. There were 898 anesthesia reports available that included blood pressure measures immediately before induction. A larger number of anesthesia records (n = 30 008) were available for intraoperative blood pressure recording. The BP decrease after anesthesia induction was most pronounced in infants 0-10 weeks of age where there was a mean arterial blood pressure (MAP) decrease of 16.6-34.5% (mean 28.6%). Systolic blood pressure decreased by 16.3-32.6% (mean 25.5%). Values above a systolic blood pressure of 60 mm Hg were only noted in half the neonates during anesthesia. Heart rates, both before and after anesthesia induction, were similar. CONCLUSION: Heart rate while under anesthesia appears a poor indicator for blood pressure changes. Recorded blood pressures in this current study, measured immediately before induction, were consistent with those in the literature. A mean MAP decrease of 28.6% was typical in those infants 0-10 weeks of age.
No takes yet. Share an insight, caveat, or question.
Sottas et al. (2016) conducted an observational in Children undergoing anesthesia (n=54,896). Anesthesia induction vs. Pre-induction baseline was evaluated on Blood pressure and heart rate changes after anesthesia induction. Anesthesia induction in infants 0-10 weeks of age resulted in a mean arterial blood pressure decrease of 28.6%, whereas heart rates remained similar before and after induction.
Synapse has enriched 10 related papers. Consider them for comparative context: