Key result
Adjunctive protective devices during percutaneous coronary procedures significantly reduced operator radiation exposure compared to standard radioprotection (12.8 vs 22.6 μSv; p<0.0001).
Why the study?
Direct comparisons among different adjunctive anti-Rx devices during percutaneous coronary procedures to reduce operator radiation exposure are lacking.
Do adjunctive protective devices reduce operator radiation exposure during percutaneous coronary procedures compared to standard radioprotection?
Observational (n=200)
No
Do adjunctive protective devices reduce operator radiation exposure during percutaneous coronary procedures compared to standard radioprotection?
Answers are grounded in this paper and cite their sources.
The use of adjunctive protective devices, particularly pelvic drapes and the Rampart system, significantly reduces operator radiation exposure during percutaneous coronary procedures.
Objective . To compare the relative effectiveness of different anti‐Rx devices in terms of radiation dose absorbed by operators during percutaneous coronary procedures (diagnostic or interventional). Background . Direct comparisons among different adjunctive anti‐Rx devices during percutaneous coronary procedures to reduce operator radiation exposure are lacking. Methods . We retrospectively analyzed the last 200 percutaneous procedures performed by a single operator according to the use of adjunctive protective devices (group 1) or standard anti‐Rx setting (group 2). Subsequently, the procedures in group 1 have been divided according to the protective device utilized (homemade pelvic drape with under‐table curtain, or RADPAD drape, or the STAR System device, or the Rampart shield). The primary endpoint was the operator radiation dose at the thorax. Results . Groups 1 and 2 did not show significant differences in terms of anthropometric data or cardiovascular risk factors. The use of adjunctive anti‐Rx devices was associated with a significant reduction in operator radiation exposure compared to standard radioprotection (12.8 μ Sv [7–21] and 22.6 μ Sv [11–36], respectively; p < 0.0001). Globally, the anti‐Rx devices utilized were associated with a reduced operator radiation exposure (11.7 μ Sv [2–19] for homemade drapes, 13.5 μ Sv [9–29] for RADPAD drape, 15 μ Sv [11–30] for STAR Board System, and 8 μ Sv [5–19] for Rampart; p < 0.0001) with the homemade drapes and the Rampart system showing a lower operator exposure. Conclusions . The use of anti‐Rx devices during percutaneous coronary procedures is associated with a significant lower operator radiation exposure with the greater effect obtained with pelvic drapes and the Rampart system.
No takes yet. Share an insight, caveat, or question.
Sciahbasi et al. (2024) conducted an observational in percutaneous coronary procedures (n=200). adjunctive protective devices vs. standard anti-Rx setting was evaluated on operator radiation dose at the thorax (p=< 0.0001). Adjunctive protective devices during percutaneous coronary procedures significantly reduced operator radiation exposure compared to standard radioprotection (12.8 vs 22.6 μSv; p<0.0001).
Synapse has enriched 10 related papers. Consider them for comparative context: