Answers are grounded in this paper and cite their sources.
We present a methodology to account for the stochastic nature of hydraulic conductivity during the design of pump‐and‐treat systems for aquifer cleanup. The methodology (1) uses a genetic algorithm to find the global optimal solution and (2) incorporates a neural network to model the response surface within the genetic algorithm. We apply the methodology for a real example and different optimization scenarios. The employed optimization formulation requires few hydraulic conductivity realizations. The presented approach produces a trade‐off curve between reliability and treatment facility size.
No takes yet. Share an insight, caveat, or question.
Aly et al. (1999) studied this question.