Answers are grounded in this paper and cite their sources.
We studied pre- to post-expedition changes in hand temperature measured by infrared (IR) thermography and energy expenditure during whole body cooling of Inspire-22 participants (6 M,3 F). Measurements were made in a whole-body calorimeter at the end of a 36-h protocol when the ambient temperature was reduced by ≈ 5.5 °C over a period of 2 h after which IR images of both hands were taken. After 1-h of re-warming, the imaging was repeated. The mean temperature of the finger and non-finger regions were determined. A line-of-best-fit and its 95% CI were used to estimate the change in energy expenditure (EE) for 100 min of cooling. Pre-expedition 5 participants showed an increased, 2 no-change and 2 decreased EE; post-expedition the corresponding values were 5, 1 and 3 respectively. There was no difference in these proportions between pre- and post-expedition measurements (χ2; p > 0.05). An Applied Rank Transform non-parametric ANOVA for small samples found no significant difference in the cool-warm temperatures for sex of the participants nor whether measurements were made pre- or post-expedition (p > 0.05). Graphical analysis showed no association between the change in EE and the change in hand-to-background temperature on cooling suggesting reduced peripheral circulation was not an explanation for reduced EE on cooling.
No takes yet. Share an insight, caveat, or question.
Hattersley et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: