Answers are grounded in this paper and cite their sources.
Considering nutrient reduction, China's wastewater treatment plants are facing the challenge to upgrade. A modelling system has been developed to screen suitable treatment processes, while statistical methods are not feasible due to data shortage. The system comprises a database to manage different treatment unit technologies, a module to generate candidate processes, a module to simulate effluent quality with material transfer functions, and a tool to identify technologies with better performance. Application of the system showed that TP is the major restrictive control index for effluent compliance. Reverse osmosis technology is preponderant under the strictest requirement.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2011) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: