Key result
Perfusion CMR at 3.0T detects significant coronary stenosis with ~0.93 AUC against FFR.
Observational (n=116)
Answers are grounded in this paper and cite their sources.
AIMS: To assess image quality and diagnostic performance of 3.0 Tesla (3T) cardiac magnetic resonance (CMR) myocardial perfusion imaging with a dual radiofrequency source to detect functional relevant coronary artery disease (CAD), using coronary angiography and invasive pressure-derived fractional flow reserve (FFR) as reference standard. METHODS AND RESULTS: We included 116 patients with suspected or known CAD, who underwent 3T adenosine myocardial perfusion CMR (resolution 2.97 × 2.97 mm) and coronary angiography plus FFR measurements in intermediate lesions. Image quality of myocardial perfusion CMR was graded on a 4-point scale (1 = poor to 4 = excellent). Diagnostic accuracy was assessed by ROC analyses using a 16-myocardial segment-based summed perfusion score (0 = normal to 3 = transmural perfusion defect) and by determining sensitivity, specificity, positive and negative predictive value on the coronary vessel territory and the patient level. Diagnostic image quality was achieved for all stress myocardial perfusion CMR studies with an average quality score of 2.5, 3.1, and 3.0 for LAD, LCX, and RCA territories. The ability of the myocardial perfusion CMR perfusion score to detect significant coronary artery stenosis yielded an area under the curve of 0.93 on ROC analysis. Values for sensitivity, specificity, positive and negative predictive value on a vessel territory level and the patient level were 89, 95, 87, 96% and 85, 87, 77, 92%, respectively. CONCLUSION: In patients with suspected or known significant CAD, 3T myocardial perfusion CMR with standard perfusion protocols provides consistently high image quality and an excellent diagnostic performance.
No takes yet. Share an insight, caveat, or question.
Ebersberger et al. (2013) conducted an observational in Suspected or known coronary artery disease (CAD) (n=116). 3.0 Tesla adenosine myocardial perfusion cardiac magnetic resonance (CMR) vs. Coronary angiography and invasive pressure-derived fractional flow reserve (FFR) was evaluated on Detection of functionally relevant coronary artery stenosis (diagnostic accuracy, sensitivity, specificity) (AUC 0.93). 3.0 Tesla myocardial perfusion CMR detected significant coronary stenosis with an AUC of 0.93, and patient-level sensitivity and specificity of 85% and 87% against angiography and FFR.
Synapse has enriched 10 related papers. Consider them for comparative context: