Why the study?
The study assessed the effect of fasting versus food and water ingestion on hepatic shear wave elastography measurements and evaluated inter- and intra-reader reliability in healthy participants.
Does the ingestion of food and water affect hepatic shear wave elastography measurements in healthy participants?
Does the ingestion of food and water affect hepatic shear wave elastography measurements in healthy participants?
Hepatic shear wave elastography measurements are significantly affected by food ingestion at 1 hour but not 3 hours, whereas water ingestion has no effect, and inter/intra-reader reliability is moderate at best.
Answers are grounded in this paper and cite their sources.
Water ingestion does not affect hepatic SWE values; leaves open effects of food intake and generalizability to patients with liver disease.
OBJECTIVES: The primary objective of this study was to assess the effect of fasting versus ingestion of food and water on hepatic measurements by shear wave elastography (SWE) in healthy participants. The secondary objective was to assess inter- and intra-reader reliability of hepatic elastography in healthy participants. METHODS: Twenty healthy participants were enrolled in this prospective study and underwent quantitative SWE under fasting conditions and after the ingestion of water and food and water. Two blinded sonographers each independently performed a total of 6 sessions of hepatic SWE in each participant. Sessions 1 to 3 were performed on day 0 and sessions 4 to 6 on day 7. Statistical tests used included the Wilcoxon signed ranks test, the intraclass correlation coefficient, and Bland-Altman plots. RESULTS: There were no significant differences in hepatic SWE measurements after the ingestion of water versus the fasting state. Statistical significance was assessed as P < 0.05. The postprandial status had a statistically significant effect on hepatic SWE measurements at 1 hour (P = .04) but not at 3 hours (P = .08). By the intraclass correlation coefficient, there was poor-to-moderate inter-reader agreement and minimal-to-moderate intra-reader agreement. The median inter-reader difference in SWE measurements ranged from 0.66 to 0.96 kPa. The median intra-reader difference ranged from 0.43 to 0.55 kPa. CONCLUSIONS: Our study shows that the ingestion of water has no effect on hepatic SWE measurements in healthy participants. The postprandial state had a significant effect on SWE measurements at 1 hour after ingestion but not at 3 hours. The inter-reader and intra-reader agreements were variable and moderate at best.
No takes yet. Share an insight, caveat, or question.
Lim et al. (2020) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: