Why the study?
Does a left femoral venous approach for ICD placement provide stable device parameters in a patient without thoracic venous access?
Does a left femoral venous approach for ICD placement provide stable device parameters in a patient without thoracic venous access?
Femoral ICD placement is a viable alternative to open chest surgery for patients requiring an ICD who lack thoracic venous access.
Answers are grounded in this paper and cite their sources.
Supports femoral ICD use when thoracic access unavailable; hypothesis-generating and requires prospective validation before broader adoption.
Evaluation of an individual requiring permanent cardiac pacing and implantable cardioverter defibrillator (ICD) function revealed no suitable thoracic vascular access for traditional device implantation. Because the patient refused cardiac surgery, a left femoral venous approach was used to introduce two extended-length, active fixation leads that were positioned in the right atrium and ventricle. The leads were tunneled to the abdomen and connected to a dual-chamber ICD. A low defibrillation threshold and robust pacing and sensing parameters were observed at implant. All of these parameters were stable at 6-month follow-up. In addition, no negative effects of the predominantly abdominal shock vector were observed. This case suggests that femoral ICD placement should be considered before routinely referring such patients for open chest surgery.
No takes yet. Share an insight, caveat, or question.
Eldadah et al. (2004) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: