Answers are grounded in this paper and cite their sources.
Methodological study demonstrates in situ direct-electron EBSD screening of ice vitrification in cryo-FIB/SEM, highlighting a streamlined workflow for cryo-TEM and atom probe preparation.
Studying biological samples such as protein complexes and cells using cryogenic transmission electron microscopy (cryo-TEM) requires vitrifying samples to preserve their structure without forming ice crystals. There exists a signficant challenge: ensuring proper sample vitrification. Previously, specimens prepared by plunge freezing, high pressure freezing (HPF), etc., required using a secondary, lower voltage screening cryo-TEM for quality control [1], [2], [3], [4]. Here we introduce the use of a highly sensitive direct electron detector (DED)-based electron backscatter diffraction (EBSD) system inside a focused ion beam (FIB) / scanning electron microscope (SEM) used to prepare lamellas for cryo-TEM and tomography [5]. This detector allows assessing ice crystallinity on-grid while in the FIB, facilitating avoiding crystalline areas and producing lamellas from improperly vitrified specimens, which give a crystalline diffraction signal. Since improper vitrification produces only one thermodynamically stable water ice polymorph, e.g. crystalline hexagonal ice 1h, the detection of hexagonal ice crystal patterns indicates TEM grid regions to avoid [6]. An integrated ultra high vacuum (UHV) cryo-transfer workflow, shown in Fig. 1, allowed to move samples from glovebox to FIB then back to glovebox and transfer out [7], [8]. We could demonstrate that this UHV cryo-transfer workflow avoids ice formation on clipped grids and successful transfer to external cryo-TEM [9]. Areas of cryo-TEM grids without crystalline signal in EBSD were used to prepare lamellae for cryo-TEM and specimens for atom probe tomography (APT), a type of nanoscale mass spectrometry. Finally, attempts to determine whether individual lamalles were crystalline after thinning using transmission Kikuchi diffraction (TKD) proved futile due to physical sample damage [10],[11]. Overall workflow (a) Vitrobot with Vitriclip used to prepare sea urchin sperm cells; (b) enlarged views of equipment; (c) custom plate and loading jig; (d) custom copper sample holder and modified Herbig holder for clipped cryo-TEM grids and clip for EBSD; (e) liquid nitrogen (LN2) filled bowl transferred into glovebox; (f) plate loading procedure; (g) metal plate immersed in LN2 bath before transfer into cryo-vacuum chamber; (h) plate transferred via elevator to cryo-vacuum chamber; (i) custom copper sample holder transferred to ultra-high-vacuum cryo-transfer-suitcase; (j) SEM view of clipped grid in SEM (k) cryo-FIB used for experiments; (l) in-chamber optical view of sample on custom copper probe holder for EBSD with 29° pre-tilt and 41° stage tilt (70° total tilt); (m) similar setup for TKD with 45° stage pre-tilt; (n) schematic depiction of electron beam, sample, and detector in FIB/STEM
No takes yet. Share an insight, caveat, or question.
Woods et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: