Potential build up and decay curves for positive corona-charged 12 μm Sheldahl FEP foils are measured and best interpreted using the conventional field dependent schubweg and a trap structure as follows: shallow traps at the polymer surface (mean life time of 103 s) and quasi-deep traps (mean detrapping time of 7 × 103 s) in the bulk. For this trap, only the product of the mobility by the trapping time is relevant (of the order of 10−10 cm2/V). Comparison between measurements in pure N2 dry air, and ambient air demonstrates that moisture has a not negligible effect on the charge transport, decreasing the surface potential. Evidence is obtained that holes trapped at the surface are located a little beneath the polymer surface confirming previous measurement by von Seggern through heat pulse technique.
No takes yet. Share an insight, caveat, or question.
Ferreira et al. (1988) studied this question.