Why the study?
Does IVUS-guided paclitaxel-eluting stent implantation reduce major adverse cardiac events compared to bare metal stents in patients with unprotected left main coronary artery disease?
Does IVUS-guided paclitaxel-eluting stent implantation reduce major adverse cardiac events compared to bare metal stents in patients with unprotected left main coronary artery disease?
IVUS-guided paclitaxel-eluting stent implantation significantly reduces major adverse cardiac events at 3 years compared to bare metal stents in patients with unprotected left main coronary artery disease.
Supports IVUS-guided PES over BMS to lower 3-year MACE in unprotected left main disease; extends randomized evidence for DES in this anatomy.
BACKGROUND AND OBJECTIVE: Recent publications have demonstrated superior outcomes in unprotected left main patients after paclitaxel-eluting stent (PES) implantation. Long-term data in these patients are limited. The aim of this study was to evaluate if intravascular ultrasound (IVUS)-guided PES implantation is superior to bare metal stent (BMS) implantation in unprotected left main disease after lesion pretreatment with cutting balloon during long-term follow-up. MATERIAL AND METHODS: Unprotected left main patients were randomized to BMS (n=50) or PES implantation (n=53). All interventions were IVUS-guided and cutting balloon pretreatment before stenting was performed in all patients. All patients were scheduled for 6-month and 3-year follow-up. Subgroups of patients who underwend IVUS and OCT imaging at 3-year follow-up were analyzed. The primary endpoint was the major adverse cardiac events (MACEs) defined as death, Q-wave myocardial infarction, or target lesion revascularization. RESULTS: Baseline characteristics were similar in both the groups with a mean SYNTAX score of 31.4±14.5 in BMS and 32.6±11.7 in PES patients (P=0.718). At 3 years, MACEs occurred in 18 patients (36.0%) in the BMS and 7 patients (13.2%) in the PES group (P=0.011). By IVUS, percent neointimal volume obstruction at 3 years was reduced from 18.1%±8.7% with BMSs to 10.0%±5.4% with PESs (P<0.001). The total number of uncovered stent struts per OCT image and IVUS image was 0.4±0.8 and 1.2±1.5, respectively (P<0.001). CONCLUSIONS: The current study demonstrated that IVUS-guided PES implantation was superior to BMS implantation after cutting balloon pretreatment in unprotected left main disease at 3 years. If compared with IVUS, OCT was more precise in the assessment of stent endothelization.
No takes yet. Share an insight, caveat, or question.
Narbute et al. (2011) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: