This paper presents an imaging-based multifunctional instrumentation system for the on-line monitoring and characterization of fossil fuel fired flames. The system includes an optical probe that transmits light from the flames in a furnace into an optical assembly, where the light is split into four beams in specific spectral ranges. Two high-performance monochromatic charge-coupled device cameras capture light from the flames and transmit the image signals to a microcomputer, where the signals are converted into digital images. Dedicated application software, incorporating novel digital image processing algorithms, two-color pyrometry, and power spectral analysis, has been developed to process the flame images. A range of flame parameters, including ignition point and area, spreading angle, brightness, nonuniformity, flicker, and temperature, are derived from the images. Experimental results obtained using a 1 MWth coal fired combustion test facility (CTF) demonstrate that the system is capable of providing instantaneous and quantitative measurement of the flame parameters on an on-line continuous basis. The flame parameters measured are found to be sensitive to combustion conditions, and therefore can be used as indicators of flame stability.
No takes yet. Share an insight, caveat, or question.
Lu et al. (2004) studied this question.
Synapse has enriched one closely related paper. Consider it for comparative context: