Answers are grounded in this paper and cite their sources.
Demonstrates improved micro-vibration control with a stinger-free system, suggesting enhanced measurement reliability.
High-fidelity broadband random micro-vibration reproduction is a fundamental prerequisite for vibration-isolation performance evaluation and metrological calibration of ultra-precision equipment. Unfortunately, conventional ground excitation systems generally rely on mechanical stingers for force transmission, which tend to introduce parasitic stiffness and nonlinear friction. Moreover, under random vibration conditions, standard control algorithms inherently suffer from noise amplification and steady-state overlearning, severely constraining the signal-to-noise ratio and metrological reliability of micro-vibration testing. To address the above issues, this paper proposes a non-contact, direct-drive ground excitation platform based on a stinger-free magneto-pneumatic hybrid suspension, combining contactless actuation via a voice-coil-motor array with air-spring pre-isolation and low-stiffness load-bearing support to establish a low-background dynamic environment with reduced parasitic stiffness and mechanical coupling. A multi-resolution adaptive frequency-domain iterative learning control (MRA-FD-ILC) algorithm is further developed. This algorithm integrates one-third-octave-band error evaluation with narrowband high-resolution spectral updating to effectively suppress stochastic variance disturbances and overlearning, thereby enabling stable convergence in random vibration spectral-shaping control. Experimental results demonstrate that the proposed system reproduces an adjustable random vibration spectrum from VC-C to VC-A over the 0.5–100 Hz frequency band. Across the VC-A–VC-C tests, the mean maximum one-third-octave band-wise absolute error did not exceed 0.78 dB, while the corresponding mean overall RMSE did not exceed 0.68 dB. The system also maintains stable spectral-shaping capability in the ultra-low-frequency range. The proposed method can provide important technical support for the performance evaluation of ultra-precision vibration-isolation systems. • A stinger-free direct-drive topology enables low-coupling random micro-vibration. • An MRA-FD-ILC strategy is developed with 1/3-octave spectral assessment. • Noise-robust gain scheduling and freezing improve reproduction stability. • VC-C to VC-A vibration is reproduced over 0.5-100 Hz with ≤ 0.78 dB error.
No takes yet. Share an insight, caveat, or question.
Yu et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: