Answers are grounded in this paper and cite their sources.
Evaluates enhanced NDWI against water indices for urban flood detection, indicating improved accuracy.
Accurately distinguishing flooded from non-flooded pixels in complex urban environments remains challenging due to spectral confusion in optical data. This study aims to reduce false alarms in urban flood detection by proposing the Enhanced Normalized Difference Water Index (ENDWI), a novel enhancement of NDWI formulated as NDWI divided by the green band, to suppress urban noise and evaluate its performance against seven established water indices. In addition, owing to the extremely narrow dynamic range of raw ENDWI values, a novel Zero-Preserving Split Normalization (Z-Split) technique is introduced to prepare ENDWI for reliable Otsu thresholding and applied exclusively to this index within this study. Z-Split expands the ENDWI histogram while strictly preserving the zero value. The approach was applied to a flash flood event in Al-Lith Governorate, a coastal urban area along the Red Sea in Saudi Arabia, selected as the case study because of its recurrent vulnerability to intense rainfall and rapid-onset flooding. Sentinel-2 imagery acquired 2 d after the event served as the core methodology for this study. Validation was performed using WorldView-4 high-resolution imagery obtained within 2 d of the event, based on 1262 ground-truth points (559 flooded and 703 non-flooded) generated within polygons to ensure consistency with the Sentinel-2 spatial resolution. Analysis of the raw indices revealed that the Automated Water Extraction Index for shadows (AWEIsh_raw) achieved the highest area under the receiver operating characteristic (ROC) curve (AUC = 0.908), followed by the Normalized Difference Water Index (NDWI_raw) (0.671) and ENDWI_raw (0.636), positioning ENDWI among the top three performers out of eight evaluated indices. Following Otsu thresholding, ENDWI_otsu achieved the highest precision (79.41 %), and the lowest false alarm rate (10.95 %) among all individual indices. A novel hybrid maximum fusion of ENDWI_raw and AWEIsh_raw further enhanced results, attaining an overall accuracy of 82.65 %, precision of 94.50 %, F1-score of 76.73 %, and Kappa coefficient of 0.637 after thresholding, with only 21 false positives (false alarm rate = 2.99 %). Overall, ENDWI exhibited robust and consistent performance across individual applications, post-thresholding, and hybrid fusion with AWEIsh, establishing it as a reliable and effective tool for accurate urban flood mapping.
No takes yet. Share an insight, caveat, or question.
Abdulrhman M. Almoadi (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: