Answers are grounded in this paper and cite their sources.
PURPOSE: Little is known regarding the influence of in-laboratory polysomnography (PSG) equipment on sleep position, especially on the prevalence of supine positioning, which in many cases may lead to a more severe sleep apnea diagnosis. The aim of this study was to assess the percentage of supine sleep during an in-laboratory PSG compared to that seen during a home sleep apnea test (HSAT). METHODS: This was a retrospective cohort study comparing in-laboratory PSG and HSAT using a peripheral arterial tone (PAT) technology device. RESULTS: Of 445 PSG and 416 HSAT studies analyzed, there was no significant difference in the proportion of supine sleep time between PSG (44%) and HSAT (45%, p = 0.53). Analysis of the differences in sleep position (supine versus non-supine), analyzed by sex, BMI (≥ 30 kg/m2 versus < 30 kg/m2), and age (≥ 60 years versus < 60 years), was significant only for women, who had more supine sleep during HSAT at 61 ± 24% than during PSG at 45 ± 26% (p < 0.001). CONCLUSION: Overall there was no difference in the percentage of supine sleep when comparing in-laboratory PSG to HSAT. However, women had more supine sleep with HSAT than with PSG.
No takes yet. Share an insight, caveat, or question.
Kukwa et al. (2020) studied this question.