Key result
Serum levels of FGF-23 and miR-208b were increased in patients with atrial fibrillation compared to healthy controls and related to disease type, cardiac parameters, and prognosis.
Why the study?
Atrial fibrillation incidence and prevalence are increasing annually as one of the most common arrhythmias, prompting investigation into the role and prognostic significance of serum FGF-23 and miR-208b.
Are serum levels of FGF-23 and miR-208b increased in patients with atrial fibrillation and related to prognosis?
Case-Control (n=390)
Are serum levels of FGF-23 and miR-208b increased in patients with atrial fibrillation and related to prognosis?
Answers are grounded in this paper and cite their sources.
Serum FGF-23 and miR-208b are elevated in patients with atrial fibrillation and may serve as biomarkers for disease severity and prognosis.
BACKGROUND: The incidence and prevalence of atrial fibrillation are increasing each year, and this condition is one of the most common clinical arrhythmias. AIM: To investigate the levels and significance of serum fibroblast growth factor 23 (FGF-23) and miR-208b in patients with atrial fibrillation and their relationship with prognosis. METHODS: From May 2018 to October 2019, 240 patients with atrial fibrillation were selected as an observation group, including 134 with paroxysmal atrial fibrillation and 106 with persistent atrial fibrillation; 150 patients with healthy sinus rhythm were selected as a control group. The serum levels of FGF-23 and miR-208b in the two groups were measured. In the observation group, cardiac parameters were determined by echocardiography. CONCLUSION: The serum levels of FGF-23 and miR-208b are increased in patients with atrial fibrillation and are related to the type of disease, cardiac parameters, and prognosis.
No takes yet. Share an insight, caveat, or question.
Chen et al. (2020) conducted a case-control in Atrial fibrillation (n=390). Serum FGF-23 and miR-208b vs. Healthy sinus rhythm was evaluated on Serum levels of FGF-23 and miR-208b (p=< 0.05). Serum levels of FGF-23 and miR-208b were increased in patients with atrial fibrillation compared to healthy controls and related to disease type, cardiac parameters, and prognosis.
Synapse has enriched 10 related papers. Consider them for comparative context: