Answers are grounded in this paper and cite their sources.
A mass spectrometer study was made to compare the transport characteristics of hydrogen and deuterium through hollow, thin walled cylinders of three types of fused quartz. The experiments in the temperature range (300°—1000°C) resulted in the following observations: (1) The permeability of hydrogen (and deuterium) in fused quartz is virtually independent of purity level or hydroxyl content. (2) The corresponding diffusivity is unaffected by purity or hydroxyl content; however, the ``anomalously low evolution rates'' which are observed at elevated temperatures in ``dry'' (low OH) quartz are much less predominant in ``wet'' quartz. (3) The total hydrogen content is higher in ``wet'' quartz. (4) The chemical exchange of diffusing (interstitial) hydrogen with residual hydrogen does not obey the same rate laws in ``wet'' and ``dry'' fused quartz. Various hydrogen trapping sites are considered in the light of infrared data and a model is proposed which accounts for the diffusion anomaly (2) as well as the exchange rate differences (4).
No takes yet. Share an insight, caveat, or question.
R. W. Lee (1963) studied this question.