Key result
Adaptive singular value cancelation (ASVC) provided more accurate ventricular activity cancelation than averaged beat subtraction, with a mean ventricular residue of 1.725 vs 3.159 in real AF signals.
Absolute Event Rate: 1.725% vs 3.159%
Adaptive singular value cancelation (ASVC) outperforms traditional averaged beat subtraction for extracting atrial activity from single-lead ECGs in atrial fibrillation.
May advance atrial activity isolation from single-lead AF ECGs; hypothesis-generating until clinically validated.
The proper analysis and characterization of atrial fibrillation (AF) from surface electrocardiographic (ECG) recordings requires to cancel out the ventricular activity (VA), which is composed of the QRS complex and the T wave. Historically, for single-lead ECGs, the averaged beat subtraction (ABS) has been the most widely used technique. However, this method is very sensitive to QRST wave variations and, moreover, high-quality cancelation templates may be difficult to obtain when only short length and single-lead recordings are available. In order to overcome these limitations, a new QRST cancelation method based on adaptive singular value cancelation (ASVC) applied to each single beat is proposed. In addition, an exhaustive study about the optimal set of complexes for better cancelation of every beat is also presented for the first time. The whole study has been carried out with both simulated and real AF signals. For simulated AF, the cancelation performance was evaluated making use of a cross-correlation index and the normalized mean square error (nmse) between the estimated and the original atrial activity (AA). For real AF signals, two additional new parameters were proposed. First, the ventricular residue (VR) index estimated the presence of ventricular activity in the extracted AA. Second, the similarity (S) evaluated how the algorithm preserved the AA segments out of the QRST interval. Results indicated that for simulated AF signals, mean correlation, nmse, VR and S values were 0.945 +/- 0.024, 0.332 +/- 0.073, 1.552 +/- 0.386 and 0.986 +/- 0.012, respectively, for the ASVC method and 0.866 +/- 0.042, 0.424 +/- 0.120, 2.161 +/- 0.564 and 0.922 +/- 0.051 for ABS. In the case of real signals, the mean VR and S values were 1.725 +/- 0.826 and 0.983 +/- 0.038, respectively, for ASVC and 3.159 +/- 1.097 and 0.951 +/- 0.049 for ABS. Thus, ASVC provides a more accurate beat-to-beat ventricular QRST representation than traditional techniques. As a consequence, VA cancelation is optimized and the AA can be extracted more precisely. Finally, the study has proven that optimal VA cancelation is achieved when a number between 20 and 30 complexes is selected following a correlation-based strategy.
No takes yet. Share an insight, caveat, or question.
Alcaraz et al. (2008) studied Atrial fibrillation. Adaptive singular value cancelation (ASVC) vs. Averaged beat subtraction (ABS) was evaluated on Ventricular residue (VR) index in real AF signals. Adaptive singular value cancelation (ASVC) provided more accurate ventricular activity cancelation than averaged beat subtraction, with a mean ventricular residue of 1.725 vs 3.159 in real AF signals.