An Al0.053Ga0.947Sb avalanche photodiode (APD) has been fabricated and tested. First, measurement of an excess noise factor as well as an ionization rate ratio has been demonstrated. A low excess noise factor of 3.8, which is 1.2 dB lower than the conventional GaInAs APD, has been obtained. From this excess noise factor, the effective value of the hole-to-electron ionization rate ratio (keff) has been determined as high as 5, being in good agreement with the hole-to-electron ionization rate ratio (β/α) given by the multiplication data. This keff value is the highest ever reported for long-wavelength III-V APDs.
No takes yet. Share an insight, caveat, or question.
Miura et al. (1989) studied this question.
Synapse has enriched 3 closely related papers on similar clinical questions. Consider them for comparative context: