Key result
Remote magnetic navigation for atrial fibrillation ablation resulted in significantly longer mean procedure times (236.87 vs. 147.22 minutes) compared to manual navigation, with no significant difference in 6-month freedom from atrial fibrillation.
Why the study?
Procedural parameters and clinical efficacy needed to be compared between remote magnetic navigation and manual navigation approaches for radiofrequency ablation in patients with atrial fibrillation.
Does remote magnetic navigation improve procedural parameters and clinical efficacy compared to manual navigation with contact-force control in patients undergoing atrial fibrillation ablation?
Cohort (n=146)
No
Does remote magnetic navigation improve procedural parameters and clinical efficacy compared to manual navigation with contact-force control in patients undergoing atrial fibrillation ablation?
Remote magnetic navigation for atrial fibrillation ablation is not superior to manual navigation with contact-force control regarding mid-term clinical outcomes and is associated with significantly longer procedure times.
Answers are grounded in this paper and cite their sources.
Longer procedure times without AF freedom benefit should not change practice; leaves open randomized trials on remote magnetic navigation.
Aims: This study aims to compare procedural parameters and clinical efficacy of remote magnetic navigation (RMN) vs. manual navigation (MAN) approach for radiofrequency ablation (RFA) in patients with atrial fibrillation (AF). Methods: 146 patients with AF were enrolled in the study. In the RMN group (n=57), patients were treated with the CARTO® 3 in combination with the Niobe ES system. In the MAN group (n=89), ablation was performed with the EnSite Velocity and TactiCath™ Quartz catheter with direct contact force measurement. Procedural time, ablation time, fluoroscopy time, radiation dose and ablation counts were measured and compared between the groups. Recurrence of AF was evaluated after 6 months of follow-up. Results: Mean procedure times (236.87±64.31 vs. 147.22±45.19 min, P<0.05), counts of RF applications (74.30±24.77 vs. 49.15±20.33, P<0.05) and total RFA times (4323.39±1426.69 vs. 2780.53±1157.85 s, P<0.05) were all significantly higher in the RMN than in the MAN group, respectively. In the same order, mean X-ray dose (9722.6±7507.4 vs. 8087.9±6051.5 mGy/cm2, P=0.12) and mean total X-ray exposure time (8.07±4.20 vs. 9.54±5.47 min, P=0.08) were not statistically different. At 6-month follow-up, freedom from AF was similar in RMN and MAN group for paroxysmal (60.8% and 73%, respectively, P=0.42) and persistent AF (69.6% and 75.0%, respectively, P=0.77). Conclusions: Due to the fact that mid-term clinical outcomes showed no significant differences in AF recurrences between groups and manual ablation strategy provided more favorable results regarding acute procedural parameters, we can conclude that the remote magnetic navigation is not superior to the manual approach.
No takes yet. Share an insight, caveat, or question.
Jež et al. (2019) conducted a cohort in Atrial fibrillation (n=146). Remote magnetic navigation (RMN) vs. Manual navigation (MAN) with contact-force control was evaluated on Mean procedure time (minutes) (p=<0.05). Remote magnetic navigation for atrial fibrillation ablation resulted in significantly longer mean procedure times (236.87 vs. 147.22 minutes) compared to manual navigation, with no significant difference in 6-month freedom from atrial fibrillation.
Synapse has enriched 10 related papers. Consider them for comparative context: