Why the study?
Does remote controlled magnetic navigation reduce fluoroscopy time compared to conventional manual ablation in patients undergoing atrial fibrillation ablation?
Does remote controlled magnetic navigation reduce fluoroscopy time compared to conventional manual ablation in patients undergoing atrial fibrillation ablation?
Remote magnetic navigation for atrial fibrillation ablation significantly reduces fluoroscopy time but increases total procedural time compared to conventional manual ablation, with comparable acute success and safety.
RMN may reduce fluoroscopy exposure during AF ablation but prolongs procedures; leaves open net benefit pending randomized trials.
Background Percutaneous transcatheter radiofrequency ablation of atrial fibrillation with remote controlled magnetic navigation (RMN) has been shown to reduce radiation exposure to patients and physicians compared with conventional manual (MAN) ablation techniques. Methods Catheter ablation for atrial fibrillation was performed utilizing RMN in 214 consecutive patients and MAN ablation techniques in 229 patients. We compared the fluoroscopy and procedural times between RMN and MAN catheter ablation of atrial fibrillation. Secondary objectives included comparing acute procedural success and short‐term complication rates between both ablation strategies. Results Fluoroscopy time was significantly shorter in the RMN group than the MAN group (53.5±30.1 vs 68.1±27.6 min, respectively; p <0.01); however, the total procedural time was longer in the RMN group (280.2±74.4 min vs 213.1±64.75, respectively; p >0.001). Further subgroup analysis of the most recent 50 ablations each from the RMN and MAN groups, to attenuate the RMN learning curve effect, showed an even greater difference in fluoroscopy time (RMN vs MAN: 53.5±30.1 vs 68.1±27.6 min), though a consistently longer procedure time with RMN (249.5±65.5 vs 186.3±65.6 min, respectively). The acute procedural success rate was comparable between the groups (98.6% vs 95.6%, respectively; p =0.07). The rates of acute complications were similar in both groups (2.3% vs 4.8%, respectively; p =0.16). Conclusions In radiofrequency ablation of atrial fibrillation, RMN appears to significantly reduce fluoroscopy time compared with conventional MAN ablation, though at a cost of increased total procedural time, with comparable acute success rates and safety profile. A reduction in procedure and fluoroscopy times is possible with gaining experience.
No takes yet. Share an insight, caveat, or question.
Lim et al. (2016) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: