Key result
In VISITAG SURPOINT-guided catheter ablation for atrial fibrillation, larger inter-tag distances were significantly associated with residual conduction and reconnections (5.3 vs. 3.7mm, p<0.001).
Why the study?
Few studies have explored the link between VISITAG SURPOINT parameters and inter-tag distance on pulmonary vein isolation in catheter ablation of AF.
What factors are associated with residual conduction and reconnection gaps during VISITAG SURPOINT-guided catheter ablation in patients with atrial fibrillation?
Observational (n=100)
What factors are associated with residual conduction and reconnection gaps during VISITAG SURPOINT-guided catheter ablation in patients with atrial fibrillation?
Larger inter-tag distances during VISITAG SURPOINT-guided ablation are associated with residual conduction and reconnections, though overall long-term success remains high.
Background: Few studies have explored the link between VISITAG SURPOINT (VS) parameters and the inter-tag distance (ITD) on pulmonary vein isolation (PVI) in catheter ablation of atrial fibrillation (AF). Objective: To examine the clinical outcomes and factors contributing to residual conduction and reconnection gaps during PVI. Methods and Results: A retrospective review of consecutive patients (N=100) with paroxysmal (n=32) or persistent AF (n=68) undergoing VS-guided ablation between 09/2018-08/2019 was performed. All procedures were performed by 2 operators. Target VS values were 425 (anterior), 375 (posterior), and 325 (in proximity of the esophagus). Target ITD was 4 mm. Acute PVI was achieved in 100% of cases, however 13 residual gaps in 12 patients were observed after the first encirclement (first pass isolation: 88%). Ten gaps due to spontaneous PV reconnections (PVR) were found in 9 patients (9%). Tags associated with these 23 gaps had similar median VS (gap-related vs. non-gap: 429 vs. 410, p=0.4545) and power (36 vs. 36W, p=0.4843), higher contact force (13.8 vs. 11.0g, p=0.0061), and larger ITD (5.3 vs. 3.7mm, p<0.001) when compared to the remaining tags. At median follow-up of 462 days (N=99 patients), freedom from any atrial arrhythmia was 84.8%. Eight patients received repeat ablation (8.1%) and of these, 6 (75%) were free from PVR. No major adverse events were noted. Conclusion: Favorable rates of first pass isolation, acute PVR, and long-term procedure success were achieved using lower VS values than in previous reports. Under these settings, larger ITDs are associated with residual conduction and reconnections.
No takes yet. Share an insight, caveat, or question.
Inoue et al. (2020) conducted an observational in Atrial fibrillation (n=100). VISITAG SURPOINT-guided catheter ablation was evaluated on Inter-tag distance (ITD) in gap-related vs. non-gap tags (p=<0.001). In VISITAG SURPOINT-guided catheter ablation for atrial fibrillation, larger inter-tag distances were significantly associated with residual conduction and reconnections (5.3 vs. 3.7mm, p<0.001).