Why the study?
The effect of the VISITAG automated tagging module on clinical outcomes after AF ablation remained unclear.
Does the use of an automated tagging module during pulmonary vein isolation reduce arrhythmia recurrence and procedure times in patients with paroxysmal atrial fibrillation?
Does the use of an automated tagging module during pulmonary vein isolation reduce arrhythmia recurrence and procedure times in patients with paroxysmal atrial fibrillation?
The use of an automated tagging module during pulmonary vein isolation for paroxysmal atrial fibrillation significantly reduces procedure, ablation, and fluoroscopy times with similar 1-year arrhythmia recurrence rates compared to conventional ablation.
Background An automated tagging module (VISITAG™; Biosense Webster, Irvine, CA) allows objective demonstration of energy delivery. However, the effect of VISITAG™ on clinical outcomes remains unclear. This study evaluated (1) clinical outcome after AF ablation using VISITAG™ and (2) the prevalence of gaps in the ablation line. Methods This retrospective analysis included 157 consecutive patients (mean age, 56.7 years; 73.2% men) with paroxysmal atrial fibrillation who underwent successful PVI between 2013 and 2016. Outcomes after the index procedure were compared between those using the VISITAG™ module (VISITAG group, n = 62) and those not using it (control group, n = 95). The primary outcome was recurrence of AF or atrial tachycardia after a blanking period of 3 months. Results The VISITAG group showed significantly shorter overall procedure time (172.2 ± 37.6 min vs. 286.9 ± 66.7 min, P < 0.001), ablation time (49.8 ± 9.7 min vs. 82.8 ± 28.2 min, P < 0.001), and fluoroscopy time (11.8 ± 5.3 min vs. 34.2 ± 30.1 min, P < 0.001) compared with controls. The 1-year recurrence-free survival rate was not statistically different between the groups (70.8% in the VISITAG group vs. 79.2% in the control group, P = 0.189). Gaps in the VISITAG line were common in the both carina and left side pulmonary veins. Patients without gaps (≥ 5 mm) by the criteria emphasizing catheter stability (> 15 s, < 4 mm range, > 60% force over time, > 6 g contact force) showed higher recurrence-free survival rate compared with those with gaps (borderline statistical significance, 91.7% vs. 66.0%, P = 0.094). Conclusion Use of the VISITAG™ module significantly reduced procedure, ablation, and fluoroscopic times with a similar AF/AT recurrence rate compared with the conventional ablation. Clinical implications of minimizing gaps along the ablation line should be evaluated further in the future prospective studies.
No takes yet. Share an insight, caveat, or question.
Cho et al. (2020) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: