Key result
Postoperative home monitoring after primary hip or knee replacement demonstrated high feasibility, achieving a mean successful wireless transmission rate of 96.4% for vital signs and pain scores.
Why the study?
Does a postoperative home monitoring system achieve ≥90% successful wireless transmissions in patients undergoing elective primary hip or knee replacements?
Observational (n=54)
No
Does a postoperative home monitoring system achieve ≥90% successful wireless transmissions in patients undergoing elective primary hip or knee replacements?
Feasibility of home monitoring after joint replacement is supported; leaves open whether it improves outcomes in randomized trials.
BACKGROUND: We conducted a prospective observational study of patients undergoing elective primary hip or knee replacements to examine the feasibility of a postoperative home monitoring system as transitional care to support patients following their surgery in real time. OBJECTIVE: The primary outcome was the mean percentage of successful wireless transmissions from home of blood pressure levels, heart rate, oxygen saturation levels, and pain scores until postoperative day 4 with a feasibility target of ≥90%. METHODS: Patients with an expected length of stay ≤1 day, age 18-80 years, Revised Cardiac Risk Index ≤ class 2, and caretakers willing to assist at home were eligible. Patient satisfaction, as a secondary outcome, was also evaluated. Wireless monitoring equipment (remote patient monitoring, Telus Canada) was obtained and a multidisciplinary care team was formed. RESULTS: We conducted the study after obtaining Research Ethics Board approval; 54 patients completed the study: 21 males, 33 females. In total, we evaluated 9 hips, 4 hip resurfacing, 26 total knees, and 15 hemi-knees. The mean transmission rate was 96.4% (SD 5.9%; 95% CI 94.8-98.0). The median response to "I would recommend the Remote Monitoring System program to future patients" was 4.5 (interquartile range 4-5), with 1 being "strongly disagree" and 5 "strongly agree." At 30 days postop, there was no mortality or readmission. CONCLUSIONS: This is an evolving new paradigm for postoperative care and the first feasibility study on monitoring biometrics after primary hip or knee replacement. Postoperative home monitoring combines current technology with real-time support by a multidisciplinary transitional care team after discharge, facilitating postsurgical care with successful wireless transmission of vitals. The postoperative home monitoring implementation is, therefore, generalizable to other surgical discharges from hospitals. TRIAL REGISTRATION: ClinicalTrials.gov NCT02143232; https://clinicaltrials.gov/ct2/show/NCT02143232 (Archived by WebCite at http://www.webcitation.org/71ugAhhIk).
No takes yet. Share an insight, caveat, or question.
Yang et al. (2018) conducted an observational in Elective primary hip or knee replacement (n=54). Postoperative home monitoring system was evaluated on Mean percentage of successful wireless transmissions from home of blood pressure levels, heart rate, oxygen saturation levels, and pain scores until postoperative day 4 (95% CI 94.8-98.0). Postoperative home monitoring after primary hip or knee replacement demonstrated high feasibility, achieving a mean successful wireless transmission rate of 96.4% for vital signs and pain scores.