This study focuses on the control of instantaneous complex power of a grid-connected voltage-source inverter (VSI). In this study, a new space-vector-modulation-based direct power control approach is proposed: the robust predictive direct power control (RP-DPC). The proposed predictive control algorithm ensures that both, instantaneous real and imaginary powers, track the reference with high speed and accuracy reducing steady-state errors. In order to reduce the total harmonic distortion (THD) in the output currents, a fundamental frequency positive sequence detector is used in conjunction with a prediction grid voltage observer. Comparative simulations and experimental results of a 10-kW three-phase grid-connected VSI showing the steady-state and transient performance of the proposed RP-DPC are given. A low THD and balanced output currents are maintained even under severe voltage unbalance conditions.
No takes yet. Share an insight, caveat, or question.
Fischer et al. (2014) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: