Answers are grounded in this paper and cite their sources.
Thermal currents have been obtained from corona-charged Mylar films exposed to a humid atmosphere for variable times. A theory that we have recently developed to account for the current ``spectrum'' of these ``near surface'' charged specimens is put into a form that facilitates routine analysis of the peaks. Exposure of Mylar to 100% RH at 50°C has a drastic effect on the four traps previously reported. After 5 days, they have completely disappeared, and only 0.6% of the total initial charge remains. Ninety percent of this latter charge is held in a trap at a depth of 2.6 eV, and the remainder at 1.3 eV. Assuming that the traps empty under monomolecular conditions, trap densities are of the order of 1014/cm3, and mobility-lifetime products, 10−8 cm2/V; to be compared with 1016/cm3 and 10−10 cm2/V for the dry samples. The thermal current spectra show, in explicit detail, how humidity affects charge storage in Mylar.
No takes yet. Share an insight, caveat, or question.
Perlman et al. (1971) studied this question.