Key result
Repeat PCI for in-stent restenosis carries a ~22% recurrent restenosis rate at 6 months.
Cohort (n=103)
Answers are grounded in this paper and cite their sources.
BACKGROUND: In-stent restenosis is an increasing clinical problem. Discordant results have been published regarding the risk of recurrent restenosis after repeat angioplasty for the treatment of in-stent restenosis. METHODS AND RESULTS: One hundred three consecutive patients (107 vessels) underwent repeat percutaneous intervention for the treatment of in-stent restenosis and were entered in a prospective angiographic follow-up program. Repeat balloon angioplasty was performed at 93 lesions (87%) and additional stenting at 14 lesions (13%). The primary success rate was 98%. Six-month angiographic follow-up was performed in 85% of eligible patients. Restenosis was determined by quantitative angiography. Restenosis defined as a >50% diameter stenosis at follow-up was observed at 22% of lesions. The rate of target-lesion revascularization at 6 months was 17%. Repeat intervention for diffuse in-stent restenosis and severe stenosis before repeat intervention were associated with significantly higher rates of recurrent restenosis. CONCLUSIONS: The overall restenosis rate after repeat intervention for in-stent restenosis is low. The subgroup of patients with diffuse and/or severe in-stent restenosis, however, is at higher risk of recurrent restenosis and may benefit from alternative therapeutic strategies.
No takes yet. Share an insight, caveat, or question.
Bauters et al. (1998) conducted a cohort in In-stent restenosis (n=103). Repeat percutaneous intervention (balloon angioplasty or additional stenting) was evaluated on Recurrent angiographic restenosis (>50% diameter stenosis) at 6 months. Repeat percutaneous intervention for in-stent restenosis resulted in a 22% recurrent angiographic restenosis rate and a 17% target-lesion revascularization rate at 6 months.
Synapse has enriched 10 related papers. Consider them for comparative context: