Why the study?
Because the course of the subclavian vein to the superior vena cava junction frequently develops lead adherences, the authors evaluated the safety and efficacy of a short 13Fr bidirectional rotational mechanical sheath as a first choice for TLE.
Does a short 13Fr bidirectional rotational mechanical sheath provide safe and effective transvenous lead extraction in CIED carriers?
Does a short 13Fr bidirectional rotational mechanical sheath provide safe and effective transvenous lead extraction in CIED carriers?
The routine first-line use of a short 13Fr bidirectional rotational mechanical sheath for transvenous lead extraction is highly effective and safe, achieving complete extraction in 95% of cases with a low complication rate.
May inform first-choice sheath selection in TLE; extends multicentric observational data but leaves comparative efficacy open.
BACKGROUND: The need for transvenous lead extraction (TLE) is increasing worldwide. Since the course of the subclavian vein until the junction with the superior vena cava is a frequent place of lead adherences, we aim to assess the safety and efficacy of a short 13Fr bidirectional rotational mechanical sheath as first choice. METHODS AND RESULTS: In this multicentric study, 202 carriers of a cardiac implantable electronic device (CIED) undergoing TLE using a short 13 Fr bidirectional rotational mechanical sheath were prospectively enrolled. All procedures were performed using a stepwise approach. The indication for TLE were infection (62%), malfunction (32%), and upgrade (6%). Overall, 471 leads were extracted: 65% pacing leads, 20% defibrillator leads, 9% coronary sinus leads, and 6% abandoned leads. Clinical success and complete lead extraction have been achieved in 97% and 95% of cases, respectively. The short sheath was always effective in gaining venous access at the start of the procedure and was sufficient for complete TLE in 67% of cases. Lead dwell time, defibrillator lead, number of leads per patient, and lead malfunction were predicting factors of long bidirectional rotational mechanical sheath use. There were no cases of intraprocedural death, and major complications were reported in 2% of patients. Overall survival was 97% at 1-year follow-up. CONCLUSION: This multicentric experience using a short 13Fr bidirectional rotational mechanical sheath reported high safety and efficacy, demonstrating the utility of routine use of short extraction sheaths of higher caliper as the first choice.
No takes yet. Share an insight, caveat, or question.
Preda et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: