Answers are grounded in this paper and cite their sources.
Shows enhanced image quality using DWB-PET/CT in patients, suggesting utility in simulating contrast-enhanced CT.
Purpose Dynamic whole-body [ 18 F]FDG PET/CT (DWB-PET/CT) imaging performed on long-axial field-of-view (LAFOV) systems enables the simultaneous assessment of tracer delivery and metabolism across extended anatomical regions. We investigated whether tracer delivery information derived from DWB-PET/CT scans could be used to generate biologically informed synthetic contrast-enhanced CT (ceCT) images using deep learning. Methods Ten patients underwent [ 18 F]FDG DWB-PET/CT and a co-registered ceCT. Voxelwise kinetic modelling was performed to derive unidirectional [ 18 F]FDG tissue clearance (K 1 ; ml g -1 min -1 ) maps which we hypothesise will correlate with CT contrast-media delivery. A deep-learning model was trained using K 1 maps and non-contrast enhanced CT (nceCT) images (for attenuation correction) as input to generate synthetic ceCT images (ceCT DWBPET-CT ). To evaluate the utility of incorporating DWB-PET/CT data, a deep-learning model was trained using only nceCT images as input (ceCT CTONLY ). Quantitative and task-orientated analyses were performed by comparing the simulated contrast enhancement for reference anatomical sites. Additionally, semi-quantitative consensus assessments were made for critical anatomical structures, image quality, and clinical usefulness of the images. Results The K 1 maps were used to obtain synthetic ceCT images which bore good visual fidelity to the ground-truth clinical ceCT images. The DWB-PET/CT data added greater value compared to a CT-only approach; the ceCT DWBPET-CT showed lower bias and lower mean percentage error compared to the ceCT CTONLY (median percentage error 2.79% vs. 8.41%) and preserved more anatomical structures with higher subjective image quality. The reference standard ceCT added additional clinical value compared to the nceCT images in 93% of cases, with the ceCT DWBPET-CT adding greater value compared to the ceCT CTONLY images (additional value added in 70% vs. 17% of cases). Conclusion We demonstrate the feasibility of using DWB-PET/CT from LAFOV to train a DL-model for generating synthetic ceCT images. The method is a potential means of simulating ceCT in cases where iv contrast is contraindicated or unavailable.
No takes yet. Share an insight, caveat, or question.
Alberts et al. (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: